İnternet sitemizde sizlere daha iyi hizmet sunulabilmesi için çerezler kullanılmaktadır.  Çerez tercihlerinizi değiştirmek ve çerezler hakkında detaylı bilgi almak için  KARNAS TEKNOLOJİ GRUP Çerez Politikası 'nı inceleyiniz.  Siteyi kullanmaya devam etmeniz durumunda KARNAS TEKNOLOJİ GRUP Çerez Politikası'nı kabul etmiş sayılacaksınız.
Kabul Ediyorum

Aten ATEN-PE0210SG

1U 16A 10Port Basic PDU/Power Distribution Unit (Elektrik Güç Dağıtım Ünitesi), Surge (Darbe) Gerilimi Korumalı

3.922,37 -₺

4.460,72 -₺

Ürün Kodu : KRNS004733

Stok mevcut : 3 gün içinde kargoya verilir.


  • Space saving -1U rack mount design
  • IEC or NEMA outlet models
  • Surge Protection
  • Over-current Protection
  • Aluminum material
  • Works with data centers, server rooms and telecom equipment

 

 

Function PE0210SA PE0210SB PE0210SG
Electrical
Nominal Input Voltage 100-120 VAC 100-240 VAC 100-240 VAC
Maximum Input Current 20A Max
(UL de-dated 16A Max)
20A Max
(UL derating 16A Max)
16A (Max)
Input Frequency 50-60 Hz 50-60 Hz 50-60 Hz
Input Connection For A Plug: NEMA L5-20P
For A2 Plug:NEMA 5-20P
NEMA L6-20P For G Plug: IEC-320 C20
For Z Plug: Chinese 16A
Input Power 2400VA(Max);
1920VA(UL de-rated)
4800VA(Max);
3840VA(UL de-rated)
3840VA(Max)
Outlet Type (10) NEMA 5-20R (10) IEC 320 C13 (10) IEC 320 C13
Maximum Output Current (Outlet) 20A Max
(UL de-dated 16A Max)
15A Max
(UL derating 12A Max)
10A (Max)
Maximum Output Current (Bank) 20A Max
(UL de-dated 16A Max)
20A Max
(UL derating 16A Max)
16A (Max)
Maximum Output Current (Total) 20A Max
(UL de-dated 16A Max)
20A Max
(UL derating 16A Max)
16A (Max)
OPD(Overcurrent Protection Device) Yes Yes Yes
Physical Properties
Dimensions (L x W x H) 48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)
48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)
48.20 x 4.44 x 4.50 cm
(18.98 x 1.75 x 1.77 in.)
Weight 0.67 kg ( 1.48 lb ) 0.67 kg ( 1.48 lb ) 0.67 kg ( 1.48 lb )
Power Cord Length 10ft(12#) 10ft(12#) 10ft(3*2.5mm2)
Environmental
Temperature (Operating / Storage) 0 – 40℃ / -20 – 60℃
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
0 – 40℃ / -20 – 60℃
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
0 – 40℃ / -20 – 60℃
*When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.
Elevation (Operating / Storage) 3000m 3000m 3000m
Compliance
EMC Verification FCC Class A FCC Class A -
Safety Verification By Request By Request LVD
Note For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.

 

Özellik Değer
Marka : Aten