Planet PL-BSP-360
Endüstriyel Tip Yenilenebilir Enerjiden Beslenen Yönetilebilir PoE+ Switch (Industrial Renewable Energy PoE+ Managed Ethernet Switch) 5-Port 10/100/1000Base-TX RJ-45 (Port 1 to Port 5, bridge mod) (Port 5, gateway mod) with 4-Port IEEE 802.3at/af PoE+ Injector (Port 1 to Port 4) (Per port 30.8 watt) 2-Port 1000BASE-SX/LX/BX SFP/mini-GBIC yuva (Port-9 ve Port-10), 100Base-FX SFP uyumlu 1 x RJ45 port (management) 1 x USB port (backup) IP30, -10~60 Derece C PoE Power Usage Display
Stok yok.
Ürün Kodu : KRNS003748
Physical Port
- 5-port 10/100/1000BASE-T Gigabit RJ45 copper with 4-port IEEE 802.3at/af PoE Injector (Port 1 to Port 4)
- RJ45 type interface for basic management and setup
- USB type A female for setting file backup and restore
Power over Ethernet
- Complies with IEEE 802.3at Power over Ethernet Plus end-span PSE
- Backward compatible with IEEE 802.3af Power over Ethernet
- Up to 4 ports of IEEE 802.3af/802.3at devices powered
- Supports PoE power up to 30 watts for each PoE port
- Auto detects powered device (PD)
- Circuit protection prevents power interference between ports
- Remote power feeding up to 100 meters
-
PoE management
- Total PoE power budget control
- Per port PoE function enable/disable
- PoE port power feeding priority
- Per PoE port power limitation
- PD alive-check
- PoE schedule
Battery Management
- Battery type option: Nickel-cadmium battery or lead-acid battery
- Easy diagnostic of the system operating status via LED indicator
- Battery current usage and status
- Battery capacity and power consumption statistics
- Low voltage cut-off protection: Send alert and cut off the low priority PoE port for the low power battery
-
Pulse Width Modulation (PWM) Protection
- Reverse current protection to prevent the current circuits from flowing back to the PV panel
- Over-current and over-temperature protection
- Reverse polarity protection (for battery and charging electrodes)
Industrial Case & Installation
- IP30 aluminum case
- DIN-rail and wall-mounted design
- Supports -10 to 60 degrees C operating temperature
- Supports ESD 6KV DC Ethernet protection
-
Redundant power design
- 24V~45V DC wide power input
Switching
- Hardware based 10/100Mbps (half/full duplex), 1000Mbps (full duplex), auto-negotiation and auto MDI/MDI-X
- Features Store-and-Forward mode with wire-speed filtering and forwarding rates
- IEEE 802.3x flow control for full duplex operation and back pressure for half duplex operation
- 8K MAC address table size
- Automatic address learning and address aging
Router
- Internet types: Dynamic IP, static IP, PPPoE, L2TP, PPTP
- Static and dynamic (RIP1 and 2) routing
- IP/MAC-based bandwidth control
- Supports Port Forwarding, DMZ, UPnP and Dynamic DNS for various networking applications
- 802.1d STP and IGMP Proxy
Security
- Port filtering lets you either allow or prevent which applications can access the Internet.
- MAC filtering allows you to include or exclude computers and devices based on their MAC address
- URL filtering allows you to control access to Internet websites in an URL list
- IP source guard prevents IP spoofing attacks
- DoS attack prevention
Management
-
Switch Management Interface
- IPv4 Web switch management- SNMP v1, v2c - Static and DHCP for IP address assignment
-
System Maintenance
- Firmware upload/download via HTTP
- Configuration upload/download through HTTP
- Hardware reset button for system reboot or reset to factory default - NTP Network Time Protocol
- SNMP trap for interface Link Up and Link Down notification
- Event message logging to remote syslog server
- PLANET Smart Discovery Utility
Hardware Specifications | |
Copper Ports |
LAN: 5 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 1 to Port 5, bridge mode) WAN: 1 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 5, gateway mode) |
PoE Injector Port | 4 ports with 802.3af/802.3at PoE injector function (Port 1 to Port 4) |
USB | 1 USB Type A female for setting backup |
Power Output |
4 PoE out 51VDC; max. 30 watts per PoE port 2 DC out 24@ 1A maximum (four-pin terminal block) * The voltage of DC out is based on the battery. |
Switch Architecture | Store-and-Forward |
Switch Fabric | 10Gbps/non-blocking |
Switch Throughput@64 bytes | 5.95Mpps@64 bytes |
MAC Address Table | 8K entries |
Shared Data Buffer | 512Kbit |
Flow Control |
IEEE 802.3x pause frame for full-duplex Back pressure for half-duplex |
Reset Button |
< 5 sec: System reboot > 5 sec: Factory default |
LED |
3 LEDs for System and Power:
4 LEDs for PoE Copper Ports (Port 1~Port 4):
1 LED for 10/100/1000T Copper Port (Port 5):
3 LEDs for PoE Power Usage (W)
|
Connector |
Removable 6-pin terminal block Pin 1/2 for PV panel; Pin 3/4 for alarm; Pin 5/6 for battery |
Alarm |
1 Digital Output (DO): Level 0: -24V~2.1V (±0.1V) Level 1: 2.1V~24V (±0.1V) Open collector to 24V DC, 100mA max. |
Power Requirements |
PV in: 24~45V DC Battery in/out: 24V DC |
Power Consumption/ Dissipation |
5.04 watts, 17.1BTU (Standby without PoE function) 6.96 watts, 23.7 BTU (Full loading without PoE function) 135.36 watts, 461.5 BTU (Full loading with PoE function) |
Dimensions (W x D x H) | 84 x 107 x 152 mm |
Weight | 1026g |
ESD Protection | 6KV DC |
Enclosure | IP30 aluminum case |
Installation | DIN-rail kit and wall-mount ear |
Power over Ethernet | |
PoE Standard | IEEE 802.3af/802.3at Power over Ethernet PSE |
PoE Power Supply Type | End-span |
PoE Power Output |
Per port 51V DC, 275mA. Max. 15.4 watts (IEEE 802.3af) Per port 51V DC, 535mA. Max. 30 watts (IEEE 802.3at) |
Power Pin Assignment | 1/2 (+), 3/6 (-) |
PoE Power Budget | 120 watts (PoE consumption + DC out and depending on power input) |
Max. Number of Class 2 PDs | 4 |
Max. Number of Class 3 PDs | 4 |
Max. Number of Class 4 PDs | 4 |
Electrical Characteristics | |
System Voltage Rating | 24V DC |
Maximum Charging Current | 6A |
Max. Solar Array VOC | 60V DC |
Max. Operating Voltage | 45V DC |
Total Current Consumption |
While operating -32mA At idle -11mA |
High Temperature Shutdown |
100 degrees C disconnect solar and load 80 degrees C reconnect solar and load |
Battery Charging Characteristics | |
Charge Algorithm | Bulk charge (constant current), Absorption charge (constant voltage) and Floating charge. Absorption and Floating charge with PWM protection. |
Maximum Output Current | 6A |
Nickel-cadmium Battery |
± 40 mV/degrees Celsius for NiCad type batteries; charge cut-off @ 55 degrees C (Temperature compensation baseline@ 25 degrees C) |
Lead Acid Battery (Default Setting) |
± 60 mV/degrees Celsius for lead acid type batteries; charge cut-off @ 55 degrees C (Temperature compensation baseline@ 25 degrees C) |
Float Charge Voltage | DC 27.2V (26.0~30.0V) |
Absorption Charge Voltage | DC 29.2V (28.0~32.0V) |
LVD (Low Voltage Disconnection) | DC 22.2V (21.0~25.0V) |
LVR (Low Voltage Reconnection) | DC 24.8V (23.0~27.0V) |
Router Features | |
Internet Connection Type |
Shares data and Internet access with users, supporting the following internet accesses:
|
Firewall |
NAT firewall with SPI (Stateful Packet Inspection) Built-in NAT server supporting Port Forwarding, and DMZ Built-in firewall with IP address/MAC address/Port/ URL filtering Supports ICMP-FLOOD, UDP-FLOOD, TCP-SYN-FLOOD filter, DoS protection |
Routing Protocol | Static/Dynamic (RIP1 and 2) routing |
VPN Pass-through | PPTP, L2TP, IPSec, IPv6 |
LAN |
Built-in DHCP server supporting static IP address distribution Supports UPnP, Dynamic DNS Supports IGMP Proxy Supports 802.1d STP (Spanning Tree) IP/MAC-based bandwidth control |
Management | |
Management Interface |
Setup of system/management functions Web firmware upgrade SNMP trap for alarm notification of events |
PoE Management |
Power limit by consumption and allocation PoE admin mode Per port power schedule Per port power enable/disable Power feeding priority Current per port usage and status Total power consumption PD alive check Scheduled power recycling |
Battery Management |
Battery current usage and status Battery capacity statistics Low Voltage Cut-Off Protection |
Standards Conformance | |
Regulatory Compliance | FCC Part 15 Class A, CE |
Standards Compliance |
IEEE 802.3 10BASE-T Ethernet IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3ab 1000BASE-T Gigabit Ethernet IEEE 802.3x Flow Control and Back Pressure IEEE 802.1D Spanning Tree Protocol IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet Plus RFC 768: UDP RFC 791: IP RFC 2068 HTTP RFC 1157: SNMP v1 RFC 1902: SNMP v2c RFC 5424: Syslog |
Environment | |
Operating |
Temperature: -10 ~ 60 degrees C Relative Humidity: 5 ~ 95% (non-condensing) |
Storage |
Temperature: -10 ~ 70 degrees C Relative Humidity: 5 ~ 95% (non-condensing) |
Özellik | Değer |
---|---|
Marka | : Planet |